A thermal power plant produces electric power of 600 KW at 4000 V, which is to be transported to a place 20 km away from the power plant for consumers' usage . It can be transported either directly with a cable of large current carrying capacity or by using a combination of step-up and step-down transformers at the two ends. The drawback of the direct transmission is the large energy dissipation . In the method using transformers , the dissipation is much smaller. In this method, a step-up transformer is used at the plant side so that the current is reduced to a smaller value. At the consumers' end , a step-down transformer is used to supply power to the consumers at the specified lower voltage . It is reasonabler to assume that the power cable is purely resistive and the transformers are ideal with a power factor unity. All the currents and voltages mentioned are rms values.
If the direct transmission method with a cable of resistance is used, the power dissipation (in %) during transmission is

tutor 0tutor 1tutor 2
Found 4 tutors discussing this question
Discuss this question LIVE
10 mins ago
Video Solution

Filo tutor solution

Learn from their 1-to-1 discussion with Filo tutors.

Solution Available
Generate FREE solution for this question from our expert tutors in next 60 seconds
Don't let anything interrupt your homework or exam prep with world’s only instant-tutoring, available 24x7
filo Logo
Question Text
A thermal power plant produces electric power of 600 KW at 4000 V, which is to be transported to a place 20 km away from the power plant for consumers' usage . It can be transported either directly with a cable of large current carrying capacity or by using a combination of step-up and step-down transformers at the two ends. The drawback of the direct transmission is the large energy dissipation . In the method using transformers , the dissipation is much smaller. In this method, a step-up transformer is used at the plant side so that the current is reduced to a smaller value. At the consumers' end , a step-down transformer is used to supply power to the consumers at the specified lower voltage . It is reasonabler to assume that the power cable is purely resistive and the transformers are ideal with a power factor unity. All the currents and voltages mentioned are rms values.
If the direct transmission method with a cable of resistance is used, the power dissipation (in %) during transmission is